-- ***************************************************************** -- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information -- -- October 26 2001, Software LAB -- -- Copyright (c) 1993-2001 by Super Micro Computer Inc. -- All rights reserved. -- -- ***************************************************************** SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF smHealth FROM SUPERMICRO-SMI; smHealthMIB MODULE-IDENTITY LAST-UPDATED "200110260000Z" ORGANIZATION "Super Micro Computer Inc." CONTACT-INFO " Software Lab Postal: 980 Rock Avenue San Jose, CA 95131 USA Tel: +1 408 503 8000 E-mail: SoftLab@supermicro.com" DESCRIPTION "MIB module for monitoring health information" ::= { smHealth 1 } SMHealthInfoTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the different types of health information that may be present in a managed device. The following health information types are currently predefined: 0: fan speed 1: voltage 2: temperature " SYNTAX Integer32 (0..64) smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 } smHealthMonitorTable OBJECT-TYPE SYNTAX SEQUENCE OF SMHealthMonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of health monitoring entries." ::= { smHealthObjects 1 } -- ================ smHealthMonitorEntry OBJECT-TYPE SYNTAX SMHealthMonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the health monitoring table. Entries cannot be created or deleted via SNMP operations." INDEX { smHealthMonitorIndex } ::= { smHealthMonitorTable 1 } SMHealthMonitorEntry ::= SEQUENCE { smHealthMonitorIndex Integer32, smHealthMonitorName DisplayString, smHealthMonitorType SMHealthInfoTypes, smHealthMonitorReading Integer32, smHealthMonitorHighLimit Integer32, smHealthMonitorLowLimit Integer32, smHealthMonitorMaxReading Integer32, smHealthMonitorMinReading Integer32, smHealthMonitorDivisor Integer32, smHealthMonitorMonitor TruthValue, smHealthMonitorReadingUnit DisplayString, smHealthMonitorStatus Integer32 } smHealthMonitorIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unique value identifies this Monitor device." ::= { smHealthMonitorEntry 1 } smHealthMonitorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual full name assigned to the Monitor device. This object is suitable for output to a human operator." ::= { smHealthMonitorEntry 2 } smHealthMonitorType OBJECT-TYPE SYNTAX SMHealthInfoTypes MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies this Monitor device type." ::= { smHealthMonitorEntry 3 } smHealthMonitorReading OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are displayed in Celsius." ::= { smHealthMonitorEntry 4 } smHealthMonitorHighLimit OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the the High limit for the Monitor device that are currently in use on the managed device. This is applied to Temperature and Voltage devices only. Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius." ::= { smHealthMonitorEntry 5 } smHealthMonitorLowLimit OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device. FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius." ::= { smHealthMonitorEntry 6 } smHealthMonitorMaxReading OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are in Celsius." ::= { smHealthMonitorEntry 7 } smHealthMonitorMinReading OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are displayed in Celsius." ::= { smHealthMonitorEntry 8 } smHealthMonitorDivisor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the value for the Divisor for the Fan device that are currently in use on the managed device. This is applied to Fan devices only." ::= { smHealthMonitorEntry 9 } smHealthMonitorMonitor OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the monitoring status for the Fan device that are currently in use on the managed device. 0 = not monitored, 1 = monitored." ::= { smHealthMonitorEntry 10 } smHealthMonitorReadingUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the reading unit of the monitor device." ::= { smHealthMonitorEntry 11 } smHealthMonitorStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the status of the monitor device. Values: 0: OK 1: Warning 2: Critical " ::= { smHealthMonitorEntry 12 } -- notifications smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 } -- (no notifications are currently defined) -- conformance information smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 } smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 } smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 } -- compliance statements smHealthCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Supermicro Health Monitoring MIB" MODULE -- this module MANDATORY-GROUPS { smHealthMonitorGroup} ::= { smHealthCompliances 1 } -- units of conformance smHealthMonitorGroup OBJECT-GROUP OBJECTS { smHealthMonitorType, smHealthMonitorName, smHealthMonitorReading, smHealthMonitorHighLimit, smHealthMonitorLowLimit, smHealthMonitorMaxReading, smHealthMonitorMinReading, smHealthMonitorMonitor } STATUS current DESCRIPTION "A collection of objects providing Monitor devices." ::= { smHealthGroups 1 } smHealthAllinoneStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the all-in-one status of the monitoring items. Values: 0: OK 1: Warning 2: Critical " ::= { smHealth 2 } smHealthAllinoneMsg OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The all-in-one status message of the monitoring items." ::= { smHealth 3 } END